登录

最新会员 最新下载

成为了本站VIP会员

12月25日 15:38

成为了本站VIP会员

12月25日 12:28

成为了本站VIP会员

12月25日 12:10

成为了本站VIP会员

12月24日 23:54

成为了本站VIP会员

12月24日 23:29

成为了本站VIP会员

12月21日 19:40
已选条件
  1. 编程语言:digsilent
  2. 代码类别:所有
  3. 发布时间:半年内
全部撤销
编程语言 更多 收起
代码类别 更多 收起
发布时间
更多选项

1. ieee 118-bus

说明:  ieee 118-bus in digsilent

1
下载
206
浏览
2021-01-19发布

2. Transmission System

  Using the SVS Interface in PowerFactory. There are a number of standard controls for SVS in the library that can be used. You will also find two standard frames in the global library (Refer to LibraryStandard ModelsComposite Model Frames). This approach is used in the attached file SVCExampleWithInterface.pfd, the SVS interface is a PowerFactory element of the class ElmSvsctrl that is setting the number of connected capacitor blocks and the angle of the thyristor control of the reactance. It also initialises the controller output to zero. This should be used with care since the consideration of the SVS control limits will be then offset by the initial SVC admittance. The interface has the advantage that operates the parallel capacitors when required.

0
下载
156
浏览
2019-03-01发布

3. Transmission System

说明:  Using the SVS Interface in PowerFactory. There are a number of standard controls for SVS in the library that can be used. You will also find two standard frames in the global library (Refer to LibraryStandard ModelsComposite Model Frames). This approach is used in the attached file SVCExampleWithInterface.pfd, the SVS interface is a PowerFactory element of the class ElmSvsctrl that is setting the number of connected capacitor blocks and the angle of the thyristor control of the reactance. It also initialises the controller output to zero. This should be used with care since the consideration of the SVS control limits will be then offset by the initial SVC admittance. The interface has the advantage that operates the parallel capacitors when required.

1
下载
180
浏览
2019-03-01发布

4. ExampleTCSC

  ExampleTCSC Category: Dynamic Simulation There are three ways of modelling an SVC system: Using the SVS Interface in PowerFactory. There are a number of standard controls for SVS in the library that can be used. You will also find two standard frames in the global library (Refer to LibraryStandard ModelsComposite Model Frames). This approach is used in the attached file SVCExampleWithInterface.pfd, the SVS interface is a PowerFactory element of the class ElmSvsctrl that is setting the number of connected capacitor blocks and the angle of the thyristor control of the reactance.

1
下载
180
浏览
2019-03-01发布

5. ExampleTCSC

说明:  ExampleTCSC Category: Dynamic Simulation There are three ways of modelling an SVC system: Using the SVS Interface in PowerFactory. There are a number of standard controls for SVS in the library that can be used. You will also find two standard frames in the global library (Refer to LibraryStandard ModelsComposite Model Frames). This approach is used in the attached file SVCExampleWithInterface.pfd, the SVS interface is a PowerFactory element of the class ElmSvsctrl that is setting the number of connected capacitor blocks and the angle of the thyristor control of the reactance.

1
下载
174
浏览
2019-03-01发布

7. ieee 9-bus

  IT IS IEEE 9 BUS TEST SYSTEM FOR DIGSILENT

3
下载
226
浏览
2018-09-21发布

8. 9BusSystem_DigSILENT

  This is a ieee 9-bus test system in Digsilent.

6
下载
170
浏览
2018-05-14发布

9. Android今日资讯新闻APP源码

  Today information app source code for android ,Today information app source code for android.

5
下载
179
浏览
2018-05-06发布