登录
首页 » Others » matlab使用gabor变换和神经网络实现人脸识别。可用。

matlab使用gabor变换和神经网络实现人脸识别。可用。

于 2020-12-05 发布
0 121
下载积分: 1 下载次数: 1

代码说明:

matlab下,使用gabor和神经网络实现人脸识别,有代码、说明文档、样例图片。亲测可用。很好的学习材料,从网上下载的。

下载说明:请别用迅雷下载,失败请重下,重下不扣分!

发表评论

0 个回复

  • stm32实现USB_存储_HID复合设备
    stm32实现USB_存储_HID复合设备,采用官方固件库实现,U盘实际上是读卡器
    2020-12-07下载
    积分:1
  • microTCA规范
    PICMG microTCA.0 Specification RC1.0ContentsIntroduction and objectives1.1 Overview1.2 Introduction1.2.1S1.2.2 MicroTCa implementation options1画1-21.2.3 Design goals1-21.2.4 Elements of microtca1-312.5 Theory of operation……着1国面1面日正1-81.3 Micro TCA enclosure types191.3.1 Single Shelf implementation191.3.2 TWo Tier mⅸ ed Width Shelf implementation.…….….….….….….….…....1-101.3.3 Two-Tier fixed Single Width Shelf implementation ....................1-101.3.4 Back-to-Back Shelf implementation.1-101.3.5 Cube Shelf implementation..1-101.3.6 Pico Shelf implementations1111.3.7 Other implementation options1111.4 Application examples1-1114.1 Base station…1-111.42 Router1-121.4.3∨ olP node.….1-121.4.4 Other Telecom Network applicationsE画1-121.4.5 Enterprise applications1-131.4.6 Other applications.....1-131.4.7 Consumer applications1-131.5 Special word usage1-131.6 Conformance1-141.7 Dimensions1-141.8 Regulatory guidelines1-141.9 Reference specifications1.10 MicroTCA0 Specification contributor……1-151-161.11 Name and logo usage1-161.12 Intellectual property……1-171.12.1 Necessary claims1,,面,国国,,国面正∴1-181.12.2 Unnecessary claims11181.12. 3 Third party disclosures1-181.13 Glossary1-192Mechanical2-12.1 Mechanical overview∴………….2-12.1.1 Terminology…2-22.1.2 Typical arrangement examples2-22.2 Dimensions, tolerances, drawing symbols, and nomenclature2-62.3 Mechanical concept2-82.4 AdvancedMC Module orientation, location, and positioning2-1624.1 Module orientation.2-162.4.2 Module positioning, horizontal--mandatory2-172.4.3 Module positioning, vertical-mandatoryU.882-192. 4. 4 Module positioning, depth--mandatory,.42-21PICMG( Micro TCAO Specification Draft RC1. 0, May 26, 2006Do not specify or claim compliance with this Draft Specification2.5 Slot detail dimensions2-222.5.1S|ot..2-222.5.2 Slot configurations, subdividing Slots2-222.5.3 Card guide, Strut, and Card Guide Support Plate(CGSP)…………2232.5.4 Optional Subrack attachment plane2-322.5.5 AdvancedMC Module--optional locking………………………2-342.6 Backplane2-3627 Subrack dimensions2-412.7.1 Mandatory Subrack2-422.8 Shelf2-472.8. 1 Shelf types.2-482.8.2 Shelf width and height…...…2-492.8.3 Shelf depth2-492.8.4 Air filter provision2-502.8.5 ESD wrist strap interface2-502.8.6 Shelf alarm LEDs2-512.9 Cable management2-522. 10 Power entry /Power Module2-562.10.1 Power Module pcb dimensions2-582.10.2 Power Module component height1·面2-632.10.3 Power module face plate2-642.10. 4 Power Module handle/Latch mechanism.2672.10.5 Power module lEDs2-672. 10.6 Power Module EMc gasketing2-672.10.7 Power Module satety covers2-672.10 8 Power module labels2-682.10. 9 Power Module Backplane Connector2-682.11 MCH Module2-692.11.1 Module types2-692.11.2 MCH PCB dimensions.2-702.11.3 MCH Subrack slot details2-772.11. 4 Plug Connector.2-792.11.5 Sequencing and contact area2-812.11.6 MCH positioning2-812. 12 Air flow management面2-822.13 Auxiliary Connector(Zone 2 and zone 3)keying2-832.13.1 Component keep- in height2-842.13.2 Connector keep-in height2-842.133 Keying block…2-852.13.5 AMC0 electrically compatible keying block2.13. 4 Keying block with electrical connections2-86.2-872.14 MicroTCa cube2892.15 MicroTCA Pico2.16 Microtca filler pane的∵面1面面,面2-902-902.17 Cooling Units(CUs)2-912.18 Subrack/Shelf/Cube/Pico performance.2922. 18.1 Load carrying2-922.18.2 Insertion cycles2922.18.3ESD2-922.18.4EMC2-93PICMG MicroTCA. 0 Specification Draft RC1.O, May 26, 2006Do not specify or claim compliance with this Draft Specification2. 18.5 Safety2-932.18.6 Physical Slot and Tier numbering2932.19 Subrack/Shelf environmental2-962.19. 1 Subrack shock and vibration2-962.19.2 Earthquake.........2-962.19.3 Flammability2-962.19.4 Atmospheric2-962. 19.5 Thermal2-972.19.6 Acoustic∴…………………2972.19.7 Surface temperatures2-972.20 References2-973 Hardware platform management3-13.1 Overview3.1.1 Micro Tca Carrier model3-13.1.3 Relationship with IPMI, AdvancedMC, and AdvancedTCA.3.1.2 MicroTCA management architecture3-23-73.1.4 Key differences from PICMG 3.0 and AMC.0 specifications..........3-73.1.5 PICMG properties and FRU Device ID assignments3-93.2 Management-related interconnects3-113.2.1 AdvancedMc interconnects3-113.2.2 Power Module and Cooling Unit interconnects3.2.3 Guidelines for OEM Module interconnects and management3-133-143.2.4 Carrier FRU Information device requirements.3-153.25 Microtca carrier interconnects3-193.3 Carrier Manager.…….…..…...…3-203.3.1 MCH Face Plate indicators3-223.3.2 Payload Interface3-223.3.3 Carrier Manager IP address3-223.3.4 IPM event support∴3-243.3.5 Redundant MCH operation3-253.3.6 Addressing3-263.3.7 Carrier number3-293.3.8 Location information34 Shelf Manager…3-383. 4.1 Shelf Manager configuration options383.4.2 Differences from the AdvancedTca shelf Manager3-403.4.3 Shelf-Carrier Manager Interface翻套国画1面,国面,1面D国画面国3-423.4.4 Shelf Manager IP addre3-433.5 MCMC requirements3453.6 EMMC requirements3-463.7 Operational state management3-483.7.1 Carrier Manager start up……….….….….………..……3483.7.2 Shelf Manager actions on Carrier detection3-483.7.3 Normal Shelf operation1B面面国B3-483.7.4 Abnormal situation handling3-4938 Power management.……3-493.8.1 Power clapping国面3-503.8.2 Micro T CA Carrier Power Management records.3-513.8.3 Early power management356PICMG( Micro TCAO Specification Draft RC1. 0, May 26, 2006Do not specify or claim compliance with this Draft Specification3.8.4 Normal power management.3-573.8.5 Power management commands and sensors3-593.8.6 Abnormal power condition handling3-673.9 Cooling management3-693.9.1 Fan geography.…3-703.9.2 Cooling control…3-713.9.3 Normal cooling operation3-723.9.4 Abnormal cooling operation3-733.9.5 Fan tachometer sensors3-733.9.6 Temperature sensors翻画1国翻B1B…3-733.10 Electronic Keying3-743.10.1 Micro TCA Carrier point-to-point connectivity information3-753.10.2 Module point-to-point connectivity information.3-773.10.3 AMC Port state commands3-783.10.4 Clock b- Keying……3-783.11 Telco alarm management3-73. 12 System Event log…………3-863.13 Sensor management3-863.13.1 Guidelines and requirements for fru sensor events3-863.13.2 MCMC SDR requirements.3-873.13.3 EMMC SDR requirements3-883.13.4 Carrier Manager SDR requirements3-883.14 fru Information.3-913. 14.1 EMMC FRU Information3-913. 14.2 MCMC FRU Information3-913.143 Carrier FRu Information3-923. 14.4 Shelf fru information面国面国面3-923.15 PMI message bridging……….3-933.15.1 Message bridging process3-933.16 PMI functions and command3-943. 16.1 Required IPMI functions..3-953.16.2 Command assignments3-973.17 FRU records, sensors and entity Ids∴3-1084 Power…4-14.1 Overview4-14.2 Loads on the Power Subsystem4-24.2.1 Microtca carrier hub(MCH),………,………………………24-24.2.2 Cooling Units4-74.2.3 Advanced mezzanine cards4-104.3 Power architecture4-134.3.1 Basic functionality4-134.3.2 Partitioning of the Power Subsystem:.::a:.4-154.3.3 Power sources4-154.3. 4 Power Subsystem redundancy4-164.3.5 System Grounding considerations4-214.3.6 Power distribution and backplane considerations4-234.4 Control and monitoring of the Power Subsystem4-2444.1 PM-EMMCs4-244.4.2 Geographic Address4-24PICMG MicroTCA. 0 Specification Draft RC1.O, May 26, 2006Do not specify or claim compliance with this Draft Specification4.4.3|PMB-04-2444.4Ps1[S|o#4-254.4.5EN[Slof]#,…4-2544.6 PWRON_[Sot]…4-254.4.7PSPM#4-2644.8 PM-EMMC watchdog timer……4264.4.9 Power Module oK4-2744.10 Power module reset4-274.4.11 System power-up4-274.4.12 Input voltage sensors1国面面量面1国面4-294.4.13 Temperature sensors4-294414 Power module extraction switch4-304,415 Blue lED4-304.4.16LED14-314 4.17 Other leds4-314.5 Connectors4-314.5. 1 Power Module Output Connector4-324.5.2 Power Module Input Connectors81国面面4-324.6 Single-Width,Fu‖- Height Power Module…∴4-334.6.1 Inputs4-344.6.2 Outputs4-354.6.3 Bulk supply current limit4-384.6.4 Control and monitoring………………………4-384.6.5 Redundancy4-384.6.6 Mechanical4-4546.7 Thermals.8...8.88.84-45画·面4.6.8 Regulatory.4-4547 Other mechanical considerations…4-464.7.1 Double-Width form factor4-464.7.2 Form factors other than Full-Height4-464.8 Power source considerations.4-464.8.1 DC power feeds4-474.8.2 AC power feeds4-554.9 References4-605 Thermal5.1 Overview5-15.2 AMC. 0 Modules and microtCa国着画5-15.3 AMC.0 Carriers and microtca5.4 Subrack slot5-25.5 Airflow path5.6 AMC.0 Modules and power dissipation.5-35-35.7 MicroTCA system cooling configuration……….….….…....545. 8 Air distribution in a slot5-45.9 Air inlet and exhaust5-55. 10 Slot cooling capability5-55. 11 Module cooling requirements●5.12 Standard air.5-75.12.1 Derivatie5.122 Barometric changes due to weather....…...……….57PICMG( Micro TCAO Specification Draft RC1. 0, May 26, 2006Do not specify or claim compliance with this Draft Specification5.13 Slot impedance curve.5-85.14 Slot fan flow curve5.15 Cooling Unit failure5-85.16 Filters5.17 System sensors….…….….……5-95.18 Thermal and operating environment5-105.19 Thermal and cabling5-105.20 Simulation and impedance testing5-105.20.1 AdvancedMC/MCH reference Module..5-115.20.2 Power Unit reference module∴5-125.21 Simulation environment5.22 Thermal dynamic modeling5-135.23 Fluid networking modeling5.24 Acoustic noise5-135.25 Surface temperature5-145.26 Design recommendations5-155.27 Cooling limitations and examples..5-175.28 References1面5-226 Interconnect6-16.1 Introduction.…6-16.2 Fabric interface6.2.1 Backplane fabric interface support requirements6-26.2.2 MCH fabric interface support requirements6.3 MCH Specific Interfaces6-46.3.1 MCH update Channel interface6-46.3.2 MCH cross-over Channel interface.6-56. 3. 3 MCH PWR ON interface6-66.3.4 Inter-MCH IPMB-L interface6.4 Synchronization clock interface6.4.1 Signal descriptions6-86. 4.2 Clock architectures6-96.4.3 Non-Telecom and Telecom clocks6-136.5 JTAG interface.…6-136.5.1 JSM Overview6-146.5.2 JSM Signaling Overview6-166.5.3 JSM Interface to mch16.54 JSM Interface to mch2.……6-186.5.5 JSM Interface to Advancedmcs.6-196.5.6 JSM Interface to Power modules.6-226.5.7 JSM Master mode selection6-236.5.8 JSM Interface to External tester..6-246.5.9 MCH JTAG6-266.5. 10 Power module jtAG6-276.6 MicroTCA Interface topologies1画6-276.6. 1 Topology models6-286.6.2 Correlation to AdvancedMc fabric regions6-296.7 MCH Connector pin allocation6-306.7.1 Pin naming conventions6-316.7.2 Fabric interface naming conventions6-31PICMG MicroTCA. 0 Specification Draft RC1.o, May 26, 2006Do not specify or claim compliance with this Draft Specification6.7.3 Synchronization clock interface naming convention6-316.7.4 MCH Connector pin list……………6-326.8 System examples.6-386.8. 1 Redundant MicroTCA system6-386.8.2 Variant redundant microtca interconnect6-416.8.3 Non-redundant MicroTCA system6-45Connectors7-17.1 General information7-17.2 AdvancedMC Backplane Connectors7-17.2.1 AdvancedMC Backplane Connector pin list7-27.2.2 AdvancedMC Backplane Connector dimensions7-27.2.3 Advancedmc backplane connector pcb layout∴7-67. 2. 4 AdvancedMC Backplane Connector electrical characteristics7-107.2.5 AdvancedMC Backplane Connector high-speed characteristics7-147.2.6 AdvancedMC Backplane Connector mechanical characteristics7-187.3 Micro TCa Carrier hub connectors7-197.3.1 Micro TCA Carrier Hub Connector pin list7-197.3.2 Micro TCA Carrier Hub mating interface design7-207.3.3 Micro TCA Carrier Hub backplane connector7-227.3. 4 Micro TCA Carrier Hub Connector Backplane PCB layout7-237. 3.5 Micro tca Carrier Hub connector electrical characteristics7-247.3.6 Micro TCA Carrier Hub Connector high-speed characteristics7-2573.7 Micro tCa Carrier hub connector mechanical characteristics7-297.4 Power Module Output Connector7.4.1 Power Module Output Connector pin list and mating sequence7-317.4.2 Power Module Output Connector dimensions7-327. 4.3 Power Module Output Connector Backplane PCb layout7-347.4.4 Electrical characteristics for power Module output connector.7-367.4.5 Power Module Output Connector mechanical characteristics7-397.5 Power Module Input Connector7.5.1 Power Module Input Connector pin list and mating sequence7-417.5.2 Power Module Input Connector dimensions7-427.5.3 Electrical characteristics for Power Module Input Connector7-477.5.4 Power Module Input Connector mechanical characteristics7-517.6 AdvancedMC Auxiliary Connector7-537.7 Test schedule7-547.7.1 Specimen measurement arrangements7-547.7.2 Test schedule tables.7-647. 8 References.7-798 Regulatory requirements and industry standard guidelines8-18.1 Regulatory……8-18.1.1 Safety8-18.1.2 Electromagnetic compatibility..……………8-28.1.3 Ecology standards.8-28.2 Telecommunications industry standards requirements8-38. 2. 1 EMC/safety requirements for the telecommunications industry.......8-38.2.2 Environmental requirements for the telecommunications industry ..............8-48.3 Reliability/MTBF standards8-7PICMG( Micro TCAO Specification Draft RC1. 0, May 26, 2006Do not specify or claim compliance with this Draft Specification8.4 Cross reference list8.5 FRU test guidelines∴8-78.5. 1 FRU safety test8-88.5.2 FRU EMC testing.8-88.5.3 FRU environmental testing8-9a Module mis-insertion considerationsA-1A 1 MCH Module mis-insertion combinationsA-2A 2 AdvancedMc module mis-insertion combinationsA-5A3 Power management implicationsA-8A 4 System management implicationsA-8A.4.1 Optional MMC instance on MCH ModuleA-9A.4.2 Using an AdvancedMC in an MCH SlotA-13A.4.3 Using an mch in an AdvancedMc SlotA-15A.4.4 Detecting mis-insertionsA-16A.5 Hardware implicationsA-1A. 5. 1 GNd pins at same locations........A-20A.5.2 PSO# and PS1# pins at same locationsA-23A.5.3 PWR and MP pins at same locationsA27A.5. 4 PWR ON pinA-29A.5.5 Ga[2: 0] pins at same locations道1面4…A-31A.5.6 ENABLE# pin at same locationA-35A.5.7 SDA L and SCL L pinsA-37A 5.8 JTAG pinsA-38A 5.9 Cross-over pinsA-39A.5. 10 TMREQ#, 12C SDA, and I2C SCL pins…A-39B Requirement list….B-1PICMG MicroTCA. 0 Specification Draft RC1.O, May 26, 2006Do not specify or claim compliance with this Draft Specification
    2020-06-05下载
    积分:1
  • 01背包穷举法
    穷举法解决背包问题,想要资源的一看题目就知道,不需要多花字数来介绍
    2021-05-07下载
    积分:1
  • Profibus master+slave+VSPD 测试软件
    Profibus master+slave+VSPD 测试软件主站+从站+虚拟串口,亲测可用
    2020-12-06下载
    积分:1
  • C++经典练习合集
    经典的C++练习题,大家可以试试,特别是对于那些刚刚入门学习C++的同学,值得一试
    2020-12-05下载
    积分:1
  • IEC61850-90-6 配电自动化
    IEC 61850标准第二版新增加的标准,IEC61850-90-6,应用于配电自动化。是个草案,对前五章进行了详细展开。
    2020-12-05下载
    积分:1
  • matlab在数据包络分析中的应用及
    系统的介绍了包络分析在实际中的应用,介绍了matlab进行包络分析的方法,并附有源程序供科研人员学习这是一个分式规划问题。若令则()可化为等价的线性规划问题:线性规划()的解和称为的最佳权向量,它们是使的效率值达到最大值的权向量。注意:作为线性规划的解,和不是唯一的义()若线性规划()的解满足:,则称为弱有效的;()若线性规划()的解中存在解并且则称为有效的。为了便于检验的有效性,一般考虑()的对偶模型的等式形式(带有松弛变量目具有非阿基米德无穷小)∑∑其中是项输入的松弛变量是项输出的松弛变量;是个的组合系数;;是个很小的止数(般取)。定理设线性规划(的最优解为则()若为弱有效()的;()若且则为有效()的程序由上一节知,要计算一个的相对效率值并讨论其(弱)有效性,须解一个线性规划若要计算所有的相对效率值,则须解个线性规划,其计算量比较大,一般须利用计算机进行计算。我们利用数学软件编写了解模型()和(的程序,比较方便地解决了的计算量大和计算复杂的问题是由公司用语言编写的著名的工程数学应用软件。它自牛推向市场以来,历经十几年的发展和竞争,现已成为国际认可的最优化的科技应用软件。目前,口经成为世界上诸多科技领域的基本应用软件。在国内、外的很多高等院校和科研机构已经十分普及。熟练地运用已成为晑校师生及科研人员的基本技能强大的矩阵运算能力和方便、直观的编程功能是我们选择它作为编写应用程序的原因。诚然,或是解线性规划问题的专业软件,但它们缺乏方便的编程功能和矩阵输入功能,在解一系列线性规划时,它们不如方便。此外,它们的普及程度远不如因此,我们认为是编写应用程序的最佳软件之一。所解的线性规划的标准形式是板小化问题:其中,是变量,是目标函数的系数向量,是不等式约枣的系数矩阵,是等式约束的系数矩阵,和分别是变量的下界和上界解线性规划()的语句为如果要解极大化问题,只须解极小化问题卜面,我们给出模型和(的程序。程序模型的程序)用户输入多指标输入矩阵用户输入多指标输出矩阵解线性规划,得的最佳权向量求出的相对效率值输出最佳权向量输出相对效率值输出投入权向量输出产出权向量程序模型(的程序)用户输入多指标输入矩阵用户输入多指标输出矩阵定义非阿基米德无穷小解线性规划,得的最佳权向量输出最佳权向量输出输出输出输出以上两个程序十分便于使用。用户只须输入多指标输入矩阵和输出矩阵,目可得到所需的结果。程序的应用设有某大学的同类型的五个系在一学年内的投入和产出的数据如下投教职工(人)教职工工资(万元)入运转经费(万元)毕业的本科生:(人)毕业的研究生(人)出发表的论文(篇)完成的科研项目(项)其中,运转经费指一学年內维持该系正常运转的各和费用,如行政小公费、图书资料费、差旅费等等。由程序,得到各系的相对效率值:以及各项投入和产出的权向量中定义,和至少是弱有效的和是非弱有效的。为了确认和的有效性并分析和非有效的原因,须利用模型(。由程序,得本问题的解:由以上解可看出:和的解中且松弛变量故由定理知,这几个系是相对有效的。和的非有效性也可以在以上解中看得一清二楚。以为例,根据有效性的经济意义,在不减少各项输出的前提下,构造一个新的投入的投入按比例减少到原投入的)倍,)并且(由非零的松弛变量可知)还可以进一步减少教职工工资万元、减少运转费用万元、多培养本科生人多完成项科研项目。对的非有效性可作类似的经济解释。结束语本文利用数学软件编写了便于使用的的计算程序,使计算量大和计算复杂的问题得到较好的解决。本文只对的模型进行了讨论。对于的另一个重要模型一模型,只须在模型(。中增加约東条件∑A,程序作相应的修攻即可。本文的程序为的理论研究和实际应用提供了方便、快捷的计算工具。参考文献:魏权龄评价相对有效性的方法北京:中国人民大学出版社盛旧瀚等里论、方法与应用北京:科学出版社,许波,刘征工程数学应用北京:清华大学出版社,
    2020-12-11下载
    积分:1
  • jsp电子商务网站源代码
    jspj2eejshtml电子商务网站源代码
    2020-11-05下载
    积分:1
  • 模糊神经网络的预测算法-嘉陵江水质评价
    神经网络预测,模糊神经网络的预测算法-嘉陵江水质评价
    2020-12-10下载
    积分:1
  • RTKLIB讲解.zip
    超级超级详细的RTKLIB,入门视频!!!教程,无痛入门,只需要知道定位的基本算法即可看懂。
    2020-06-27下载
    积分:1
  • 696518资源总数
  • 104226会员总数
  • 29今日下载