INVERTERPWMcompensater
代码说明:
compensation of dead time effect of the inverter dead time effect causes the impact of the control performance of the INVERTER system, and pointed out that the dead time compensation, the key lies in the current phase of the acquisition, in order to overcome the practical zero of the current ambiguity of the system is proposed based on the two-phase stationary coordinate system under the feedforward dead-time compensation method. by the offset voltage of the three-phase output current cycle Fourier transform is found only compensation 1, 5, 7 harmonic components to eliminate the dead time effect. simulation and experimental results verify the correctness and feasibility of this approach.
下载说明:请别用迅雷下载,失败请重下,重下不扣分!